Dissolved Oxygen Sensors

|
|
|
 |
| Description |
13mm diameter Dissolved Oxygen sensor
suitable for Laboratory and limited Field work. Detachable cable
design allows the user to change cables without having to purchase
additional sensors.
Submersible to 3 metres. For intensive field use (eg. aquaculture),
TPS recommends the more rugged EDYSI sensor , below. |
| Range |
0 to 200% Saturation |
| Temperature
Range |
0 to 45 OC (32 to 113 OF) |
| Cathode |
Gold, 4mm diameter. |
| Anode |
Silver |
| Temperature
Compensation |
Dual ATC system for membrane permeability
and dissolved oxygen solubility (the latter applies to ppM mode
only). |
| Dimensions |
130 x 13 mm |
| Ordering |
| Description |
Part No |
ED1 Dissolved Oxygen Sensor (no
cable)
for Portable and Benchtop instruments |
123400 |
| 1m cable for Aqua, WP, smartCHEM
& MC Series |
123228 |
| 3m cable for Aqua, WP, smartCHEM
& MC Series |
123230 |
| 5m cable for Aqua, WP, smartCHEM
& MC Series |
123232 |
| 1m cable for 900 Series |
123234 |
| 3m cable for LC82, 440 & 2052A |
123238 |
| 5m cable for LC82, 440 & 2052A |
123240 |
| Extra cable (order by the metre) |
130040 |
| ED1M Dissolved Oxygen Sensor (no
cable) for Process Monitor & Control instruments |
123440 |
| 5m cable for TPS Process Monitors
and Controllers |
123236 |
| Extra cable (order by the metre) |
130040 |
|
Download the ED1 Instruction Sheet . |
|
|

|
|
|
 |
| Description |
The renowned YSI-5739 dissolved oxygen
sensor is extensively in field and industrial applications. It is an
extremely rugged design, and features a pressure compensating
diaphragm which allows the sensor to be submersed to 60 metres. The
detachable cable design allows the user to change cables without
having to purchase additional sensors. This sensor is highly
recommended for aquaculture applications. |
| Range |
0 to 300% Saturation |
| Temperature
Range |
-5 to 45 OC (23 to 113 OF) |
| Cathode |
Gold |
| Anode |
Silver |
| Temperature
Compensation |
Dual ATC system for membrane permeability
and dissolved oxygen solubility (the latter applies to ppM mode
only). |
| Dimensions |
105 x 22 mm |
| Ordering |
| Description |
Part No |
| EDYSI Dissolved Oxygen Sensor
(no cable) |
123204 |
| 1m cable for WP & smartCHEM
Series |
123212 |
| 3m cable for WP & smartCHEM
Series |
123221 |
| 5m cable for WP & smartCHEM
Series |
123222 |
| 1m cable for 900 Series |
123225 |
| 3m cable for 90 Series |
123215 |
| 5m cable for 90 Series |
123219 |
| 7.5m cable for 90 Series |
123216 |
| 15m cable for 90 Series |
123217 |
| 60m cable for 90 Series |
123218 |
| 1m cable, Process
Monitors/Controllers |
123211 |
| 3m cable, Process
Monitors/Controllers |
123205 |
| 5m cable, Process
Monitors/Controllers |
123210 |
| 7.5m cable, Process
Monitors/Controllers |
123206 |
| 15m cable, Process
Monitors/Controllers |
123207 |
| 60m cable, Process
Monitors/Controllers |
123208 |
| Plug to suit YSI brand meters |
123209 |
| Extra cable (order by the metre) |
130040 |
|
Download the YSI-5700 Series Instruction Sheet . |
|
|

|
|
|
 |
| Description |
YSI-5750 Dissolved Oxygen sensor with
tapered body for standard BOD bottles. Supplied with a fixed 1.5m
cable. |
| Range |
0 to 300% Saturation |
| Temperature
Range |
-5 to 45 OC (23 to 113 OF) |
| Cathode |
Gold |
| Anode |
Silver |
| Temperature
Compensation |
Dual ATC system for membrane permeability
and dissolved oxygen solubility (the latter applies to ppM mode
only). |
| Dimensions |
80 x 22 mm |
| Ordering |
| Description |
Part No |
EDYSIB BOD Sensor
Please specify the instrument with which this sensor is to
be used when ordering, so that the correct connector is
fitted. |
123214 |
|
Download the YSI-5700 Series Instruction Sheet . |
|
|

|
|
|
 |
| Description |
YSI-5905 Dissolved Oxygen sensor with
tapered body for standard BOD bottles. Fitted with an integral
stirrer for accuracy and convenience. Supplied with a fixed 1.5m
cable and AC/DC Adaptor. |
| Range |
0 to 300% Saturation |
| Temperature
Range |
15 to 35 OC (59 to 95 OF) |
| Cathode |
Gold |
| Anode |
Silver |
| Temperature
Compensation |
Dual ATC system for membrane permeability
and dissolved oxygen solubility (the latter applies to ppM mode
only). |
| Dimensions |
50 x 20 mm (sensing section only) |
| Ordering |
| Description |
Part No |
EDYSIB BOD Sensor
Please specify the instrument with which this sensor is to
be used when ordering, so that the correct connector is
fitted. |
123213 |
|
Download the YSI-5905 Instruction Sheet . |
|
|

|
Download this Specification Sheet in PDF format.
For a copy of the YSI instruction leaflet, please contact
TPS.
Hint : Right click on a link, then
select "Save Target As..." or "Save Link
As..." to save the file to your own computer.
If you do not have Adobe Acrobat in your computer, a free Acrobat
Reader can be downloaded by clicking on the following link.

|
TPS reserves the right to change any part of this
specification without notice.
Version 1.0
Copyright © 2003 T.P.S. Pty Ltd |
|