TPS_Logo.gif (100759 bytes)   


 

TPS Australia - Quality instruments since 1968.

Nothing's as cool, as a freshwater pool

poolCHEM-1 ORP and pH Controller
for Pools and Spas

The Plus Pack, which was previously optional, is standard from 2005.

poolCHEM-1

Full size image

Automatic controller for ORP and pH in Swimming and Spa Pools. 

The poolCHEM-1 has 1 inbuilt peristaltic pump, which can be set up to control ORP or pH. A 24V DC output is provided for controlling the other channel. This

For example...

bullet Control liquid Chlorine with the inbuilt pump and use the 24V DC output to control a Carbon Dioxide valve for pH Control.
bulletControl pH with acid using the inbuilt pump and use the 24V DC output to control a larger Chlorine dosing pump (external relay may be required).

Temperature readout is provided. Supplied with sensors, calibration standards and all accessories required for installation.

The new advanced design makes this unit far superior and yet easier to use than other brands. The poolCHEM-1 is the culmination of over 30 years  manufacturing experience. 

bulletWaterproof construction rated to IP65.
bulletOne 6L/Hr peristaltic pump built in.
bulletSupplied with 24V DC output control cable for low-powered devices or relay etc for second channel.
bulletMemory for 2300 stored readings, with automatic datalogging facility.
bulletRS232 Interface for remote monitoring of system (cable is optional).
bulletPump sensor only allows automatic dosing when circulating pump is on.
bulletGraphic display mode makes the data easy at a glance.
bulletAutomatic calibration
bulletConfigure with pool size for quick set-up
bulletOperates off a single AC/DC power supply. No electrical installation required.
bulletSupplied complete with Sensor / Injection pipe fitting.
bulletQuick-dose function
bulletTemperature readout.
bulletFully adjustable ON and OFF times can be set separately for ORP and pH pumps, eliminating over-dosing.
bulletUser can select acid or alkali addition.
bulletPassword protection, so only qualified users can change set-up or calibration.
bulletGood laboratory practices (GLP) function brings analytical Q.A. to swimming pools. Instant recall of current calibration and system set-up information.
bullet24 Hour calendar clock.
bulletEmergency shutoff timer shuts off ORP and pH pumps if they operate continuously for user-set time.


Specifications

ORP
Range      : 0  to 1000 mV
Resolution : 1 mV
Accuracy   : +/-1 mV

pH
Ranges     : 2.0  to 12.0 pH
             2.00 to 12.00 pH
             (user selectable)

Resolutions: 0.1 pH
             0.01 pH
Accuracy   : +/-0.01pH

Temperature
Range      : -10.0 to 120.0 OC
Resolution : 0.1 OC
Accuracy   : +/-0.2 OC

Temperature Compensation
Automatic Temperature Compensation for pH. Uses temperature sensor built into
ORP sensor

Calibration
Automatic calibration for all parameters, with automatic standards recognition.

Enclosure
Tough ABS enclosure, fully waterproof to IP65.

Display
80 Character alphanumeric LCD with user-friendly menu system and full-text messages.

Dimensions
210 x 180 x 90 mm

Mass
Full Kit    : Approx 3.0kg

Environment
Temperature : 0 to 45 OC
Humidity    : 0 to 95% R.H.

Peristaltic Pump

bullet1 x built-in 6 Litre/ Hour
bulletChemical resistant Santoprene pump tubing
Good Laboratory Practices
All calibration information and user-adjustable set-up information is stored in memory, and can be recalled on the display at any time. This information can also be printed or downloaded to a computer, when the optional RS232 cable is fitted.

The unit's serial number is stored in memory. This is displayed at turn-on, and included with GLP information.

Plus-Pack
(previously optional, but standard from 2005)
The Plus Pack includes the following items...
bulletRS232 Serial Interface
bulletDatalogging capability
bullet24 Hour Calendar Clock
bulletSelectable High or Low

Datalogging
Memory
2300 readings, including date and time.

Notepad
Records reading into memory at the touch of a button.

Automatic Datalogging
User selectable for one reading every...
1,2,5,10,15,20 or 30 minutes
or every...
1,2,3,4,6,8,12 or 24 hours

RS232 Serial Interface
300, 9600 and 19200 Baud.
8 Bits, No Parity, 1 Stop Bit, XON/XOFF Protocol
Note : RS232 cable is optional.

Calendar Clock
24 Hour Calendar Clock


Ordering Information 

                           Part No
poolCHEM-1 Controller.......111114

Kit Includes
pH Sensor, 2m...............111230
ORP/Temp Sensor. 2m.........111263
Inductive Pump Sensor.......130102
pH6.88 Buffer, 200mL........121306
pH4.00 Buffer, 200mL........121381
231mV ORP Standard..........121309
Sensor/Injection Tee........117904
50 to 40mm Bushes x 2.......NPBR5040
24VDC Control Output Cable
Pump Input/Output Tube, 4m
..116360
Drum Lid tube fitting
.......116362
Tube weight for drum
........116354
AC/DC Power Adaptor.........Specify
                            Country
poolCHEM Manual.............130050

No other items are required to install and operate the poolCHEM-1

                           Part No
Spares
Pump Tube assembly, 1.8L/Hr.116353
Pump Tube assembly, 6.1L/Hr.116352
Pump Tube Lubricant, 3mL....130103

Instrument Options
RS232 Interface Cable.......130041

Communication Software
for Windows.................130086

Alarm Siren (105dB).........130101

Download this Specification Sheet in PDF format.

Download the full colour TPS Pool Products Brochure (2.05 MB PDF).

Download the manual for this instrument.

Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer.

If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link.

 

TPS reserves the right to change any part of this specification without notice.
Version 2.0
Copyright © 2002, 2005  T.P.S. Pty Ltd

Web Author : TPS Pty Ltd
Copyright © 2002-2010 T.P.S. Pty Ltd
A.B.N. 30 009 773 371
Last modified: June 03, 2010