bulletAutomatic controller for ORP plus preset pH feeder in Swimming and Spa Pools. The 
bulletSupplied with sensors, calibration standards and all accessories required for installation and operation.

bulletFast and easy to install.

bulletWater resistant to IP25.

bulletEasy to use.

bulletDesigned for domestic and small commercial pool installations.

bulletTo see how quick and easy the easyCHEM 550 is to install, ask for a copy of the installation guide.

Features

Benefits

Controls Chlorine with ORP reading, and adds preset amount of Acid per day. The easyCHEM 550 is a simpler version of it's big brother, the easyCHEM 770. The easyCHEM 550 monitors ORP and controls the Chlorine levels accordingly. The unit adds the same amount of Acid per day, according to the Litres per Day setting, which can be set by the user.

Pool Pump Timer Output
Pump Timer controls the main pool pump. Unit offers Summer, Winter, Auto and Custom modes. 

Summer mode pumps 4 hours in the morning, 4 hours in the afternoon. 

Winter mode pumps 4 hours in the afternoon only. 

Auto mode automatically changes to Winter mode on 15th May and returns to Summer mode on 15th August. (15th November & 15th February respectively for the Northern Hemisphere). These dates can be customised by the user.

Custom mode allows user to enter 1 or 2 pumping cycles per day at times of their choice.

Installer does not have to purchase and install a separate pool timer. Just one power point is required. Saves installation time & money. 

Ensures controller only adds chemicals when the pump is actually running. 

Clock has battery back-up so no need to reset in case of power failure.


Inbuilt Peristaltic Dosing Pumps

Peristaltic pumps are far more reliable than solenoid valves. If a valve on the suction side of a pump leaks when it supposed to be closed, that whole drum of chemical will be dosed into the pool. 

Peristaltic pumps have positive displacement, so injection can occur in the return line, after the filter and any heating equipment. 

The benefit of peristaltic pumps is therefore higher reliability and longer life for other pool equipment.


Unit is fully calibrated and has most the common set-up defaults when it leaves the factory.
Easy Pool Size entry sets up correct automatic control function. Choice of the following settings...
  Spa 
  20,000 Litres 
  50,000 Litres 
100,000 Litres
Installation is simplified. Just mount the controller and tee piece, connect the probes and switch it on. The default settings are suitable for pools between 50,000 and 100,000 Litres.

Saves time. Prevents errors. 

Unit provides easy control set-up by inputting pool size for other size pools and spas.


Single probe and chemical injection tee
The single probe mounting and chemical injection assembly is made from a standard 50mm PVC Tee. Reduction bushes are supplied in the kit for 40mm pipe installations. The installer saves time and money by breaking into the return line at only one point. No special tools or drilling etc are required.

Fully waterproof enclosure.
The easyCHEM 550 has been independently tested for conformance with IP25 weather resistance.  The sensor connectors are IP65 (hose-proof). The easyCHEM 550 is suitable for outdoor use, however a separate shelter is desirable.

The superior design of the 24VDC pumps means the entire unit runs cooler than other brands which use 240V AC pumps.


32 character alphanumeric display

User-friendly text messages in simple English are provided for control status, alarms, set-up messages etc. No obscure codes or flashing lights which confuse most people.

The menu system makes it a breeze to change settings or check operation of the unit.


Full function keypad

All day-to-day operations are directly accessed with a single keypad button, simplifying operation. More complex set-up tasks are accessed via a separate "Tech Menu" key.

Super-Chlorinate Function
Operator can enter how many litres of Chlorine they wish to add.

The pool pump is always run for 4 hours when super chlorination is complete, ensuring total mixing.

End-user or pool service professional does not need to handle liquid chemicals for super-chlorination. The easyCHEM 550 handles it for you, and returns to normal control operation afterwards.

Pool Backwashing Function
The easyCHEM 550 prompts the user to set the filter control to Backwash, Rinse and Normal Filtration as required. The pool pump is switched off whenever the filter control is being changed.

Chemical addition is disabled while backwashing.

Makes backwashing simple for home users, helping to ensure clean, hygienic water.

Pump to Waste Function
The easyCHEM 550 prompts the user to set the filter control to "Pump to Waste" and Normal Filtration as required. The pool pump is switched off whenever the filter control is being changed.

Chemical addition is disabled while pumping to waste.

Makes draining the pool simple for home users. Normally only used after periods of heavy rain.

Dosing Pump ShutOFF feature
If the Chlorine pump has operated continuously for more than a user-selectable time, it will shut down. Stops the pump operating dry when the Chlorine drum is empty. 

Stops a whole drum of Chlorine being added to a pool in case there is an instrument or probe fault.


Alarm Function 
If the ORP reading goes beyond the Set Point(s) by a preset amount for a preset time, the internal beeper will sound and the display will show an alarm message. The easyCHEM 550 continues automatic control to attempt to bring the ORP reading back within the Set Point. Safeguards against overdosing or underdosing in case of instrument or probe fault.

Service/Calibration Interval Message
Displays a friendly message at factory-set intervals, informing the user that it's time to check and calibrate the sensors (every 3 months) and lubricate pump tubes (annually). Ensures that the unit is regularly maintained and calibrated, providing for the best possible accuracy and pool water quality.


Specifications

ORP
Range      : 0  to 999 mV
Resolution : 1 mV
Accuracy   : +/-1 mV

Temperature
Range      : -10.0 to 120.0 OC
Resolution : 0.1 OC
Accuracy   : +/-0.2 OC

Calibration
Automatic calibration for ORP and Temperature.

Enclosure
Tough ABS enclosure tested to IP24. Temperature sensor connector is rated to IP65.

Display
32 Character alphanumeric LCD with user-friendly menu system and full-text messages.

Dimensions
265 x 185 x 130 mm (controller only)

Mass
Instrument only : Approx 1 kg
Full Kit        : Approx 5 kg

Environment
Temperature : 0 to 45 OC
Humidity    : 0 to 95% R.H.

Peristaltic Pumps
bullet2 x built-in Peristaltic Pump.
Max 1.8L/Hr with small tubes
Max 6.1L/hr with large tubes
bulletChemical resistant Santoprene
pump tubing

Calendar Clock
24 Hour Calendar Clock.
Battery back-up in case of power failure will last for >10 years.

Power
220/240V AC, 5 watts max for controller.
Can be factory-set for 110/120 V AC


Ordering Information

                           Part No
easyCHEM 550 Controller.......117551

Kit Includes
ORP Sensor, 2m................111230
Temperature Sensor, 2m........124230
231mV ORP Standard............121309
Sensor/Injection Tee..........117904
50 to 40mm Bushes x 2.......NPBR5040
Pump Input/Output Tube,4m x2..116360
Drum Lid + tube fittings x2...116362
Tube weights for drum x 2.....116354
easyCHEM 550 Handbook.........130050

No other items are required to install and operate the easyCHEM 550.

                           Part No
Spares
Pump Tube assembly, 1.8L/Hr.116353
Pump Tube assembly, 6.1L/Hr.116352
Pump Tube Lubricant, 3mL....130103
Download this Specification Sheet in PDF format.

Download the full colour TPS Pool Products Brochure (2.05 MB PDF).

Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer.

If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link.

 

TPS reserves the right to change any part of this specification without notice.
Version 1.0
Copyright © 2002 T.P.S. Pty Ltd

Web Author : TPS Pty Ltd
Copyright © 2002-2005 T.P.S. Pty Ltd
A.B.N. 30 009 773 371
Last modified: September 17, 2007