TPS_Logo.gif (100759 bytes)   


 

TPS Australia - Quality instruments since 1968.

hydroCHEM-DS Conductivity and pH
Dosing System

hydroCHEM-DS Image

Full Size Image

bulletFully configured controller for Conductivity and pH in Hydroponic applications.

bulletTemperature readout is provided, and optional temperature control output is optionally available. All components are pre-installed onto the single panel. All that the end-user needs to do is cut the tubing to the desired lengths plug it in and turn it on. Low maintenance, reliable peristaltic pumps. Supplied with all fittings and accessories. 

bulletThe new advanced design makes this unit far superior and yet cheaper and easier to use than other brands. The hydroCHEM Dosing System is the culmination of over 30 years  manufacturing experience. 

bulletThe hydroCHEM Dosing System is quite simply the best hydroponics controller available anywhere in the world in its price bracket.
bulletPre-installed onto mounting panels. No further installation required.
bulletWaterproof construction rated to IP65.
bulletHighly reliable peristaltic pumps included.
bulletMemory for 2300 stored readings, with automatic datalogging facility (optional).
bulletRS232 Interface for remote monitoring of system (optional).
bulletFlow sensing to ensure system functions correctly.
bulletLarge digit mode makes the data easy to read in any light or from a distance.
bulletAutomatic calibration
bullet4 Terminal conductivity sensor technology resists fouling for maximum reliability.
bulletUser can choose readout in mS/cm, CF units, dS/M or ppM (TDS).
bulletQuick-dose function
bulletTemperature readout with optional temperature control output.
bulletFully adjustable ON and OFF times can be set separately for Conductivity and pH pumps, eliminating over-dosing.
bulletUser can select acid or alkali addition.
bulletPassword protection, so only qualified users can change set-up or calibration.
bulletGood laboratory practices (GLP) function brings analytical Q.A. to the hydroponics farmer. Instant recall of current calibration and system set-up information.
bullet24 Hour calendar clock (optional).
bulletEmergency shutoff timer shuts off Conductivity and pH pumps if they operate continuously for user-set time.
bulletOperates off a single AC/DC power supply. No electrical installation required.


Specifications

pH
Ranges     : 2.0  to 12.0 pH
             2.00 to 12.00 pH*
Resolutions: 0.1 pH
             0.01 pH*
Accuracy   : +/-0.01pH

Conductivity
Ranges     : 0 to 9.9 mS/cm
             0 to 9.99 mS/cm*
             0 to 99 CF
             0 to 99.9 CF*
             0 to 9.9 dS/m
             0 to 9.99 dS/m*
Resolutions: 0.1 mS/cm
             0.01 mS/cm*
             1 CF
             0.1 CF*
             0.1 dS/m
             0.01 dS/m*
Accuracy   : +/-0.5% of full
             scale

TDS
Ranges     : 0 to 9.9 ppK
             0 to 9.99 ppK*
Resolution : 0.1 ppK
             0.01 ppK*
Accuracy   : +/-1.0% of full
             scale

Temperature
Range      : -10.0 to 120.0 OC
Resolution : 0.1 OC
Accuracy   : +/-0.2 OC

Temperature Compensation
Automatic Temperature Compensation for Conductivity, TDS and pH. Uses temperature sensor built into Conductivity sensor

Calibration
Automatic calibration for all parameters, with automatic standards recognition.

Enclosure
Tough ABS enclosure, fully waterproof to IP65.

Display
80 Character alphanumeric LCD with user-friendly menu system and full-text messages.

Dimensions
1 panel 235 x 300mm and 
1 panel 470 x 300mm

Mass
Full Kit        : Approx 8.0kg

Environment
Temperature : 0 to 45 OC
Humidity    : 0 to 95% R.H.

Good Laboratory Practices
All calibration information and user-adjustable set-up information is stored in memory, and can be recalled on the display at any time. This information can also be printed or downloaded to a computer, when the optional Plus Pack is fitted.

The unit's serial number is stored in memory. This is displayed at turn-on, and included with GLP information.

Plus-Pack Option
The Plus Pack option includes the following items...
bulletRS232 Serial Interface for
bulletDatalogging capability.
bullet24 Hour Calendar Clock.
bulletSelectable High or Low

Datalogging*
Memory
2300 readings, including date and time.

Notepad
Records reading into memory at the touch of a button.

Automatic Datalogging
User selectable for one reading every...
1,2,5,10,15,20 or 30 minutes
or every...
1,2,3,4,6,8,12 or 24 hours

RS232 Serial Interface*
300, 9600 and 19200 Baud.
8 Bits, No Parity, 1 Stop Bit, XON/XOFF Protocol

Calendar Clock*
24 Hour Calendar Clock

Peristaltic Pumps

bullet3 x 6 Litre/ Hour
bulletChemical resistant Santoprene

Power
24V DC, 300mA Max with both pumps on.
AC/DC Adaptor to suit specified country is supplied.

*These items applicable when Plus-Pack option is fitted.


Ordering Information

                       Part No
hydroCHEM-DS Dosing.....111109
System with peristaltic pumps,
sample chamber and mounting
panel

Kit Includes
hydroCHEM Controller....111103
Dosing Panel with 3.....116320
pumps and sample chamber
4 Terminal Cond Sensor..122205
(also used for temperature
and flow detection)
Gel-filled pH Sensor....121227
pH6.88 Buffer, 200mL....121306
pH4.00 Buffer, 200mL....121381
2.76mS/cm Conductivity
Standard, 200mL.........122306
AC/DC Power Adaptor....Specify
                       Country
3 x 2m Input Tubing.....116358
3 x 2m Output Tubing....116360
3 feed drum weights.....116354
10m of 13mm Poly Tube...NPH.5
4 x 13mm Poly Clips.....NC13
hydroCHEM Manual........130050

                       Part No
Instrument Options
Plus-Pack option........130100
(includes RS232 cable)

Communication Software
for Windows.............130086

Spares
RS232 Interface Cable...130041
Pump Tube Assembly......116352
Pump Tube Lubricant,3mL.130103

Download this Specification Sheet in PDF format.

Download the full colour Hydroponics Products Brochure (2.08 MB PDF).

Download the manual for this instrument.

Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer.

If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link.

TPS reserves the right to change any part of this specification without notice.
Version 4.0
Copyright © 2002 TPS Pty Ltd

Web Author : TPS Pty Ltd
Copyright © 2002-2010 T.P.S. Pty Ltd
A.B.N. 30 009 773 371
Last modified: June 03, 2010