TPS_Logo.gif (100759 bytes)   


TPS Australia - Quality hand-made instruments since 1968.

90-D Portable Dissolved Oxygen
and Temperature Logger

90-D Image
(90-FL shown. 90-D is almost identical)

Full Size Image

bulletFully waterproof enclosure

bullet80 character display with user-friendly menu's and full-text messages.

bulletWide range of measurements

bulletSensor is submersible to 60m.

bulletAutomatic calibration

bulletAutomatic datalogging and Computer interfacing available
The TPS 90-D is a complete Dissolved Oxygen and Temperature logger.

User-friendly
The 80 character display shows Dissolved Oxygen, Temperature, Date and Time simultaneously. The user-friendly menu system guides the operator through all operations such as calibration, setup etc. Full text help and error messages are provided along the way.

Waterproof
The 90-D is designed for rugged field applications in wet environments. The case, keypad and connectors are rated to IP65.

Good Laboratory Practices
To comply with GLP guidelines, the date, time and results of the last calibration are stored in memory, along with the unit's serial number. This data can be displayed or sent directly to the RS232 port. Warning of failed calibration is provided. All readings stored in memory are stamped with the date and time.

Notepad Function
A standard feature of the 90-D is the Notepad function. Up to 9340 readings can be recorded for later review. These can be downloaded to a printer or computer via the RS232 port. For added functionality, the user is able to enter up to two additional items to be tagged on to the reading. Many operators use this function as a site identifier, depth or readings from other instruments.

Datalogging
Automatic datalogging provides the capability to automatically record up to 9340 sets of readings at user-set intervals. The unit remains dormant between readings and only wakes up whenever a reading is due. Battery life is considerably improved with this facility.

RS232 Port
All recorded data can be sent directly to a Printer or PC with the standard RS232 port (cable sold separately). The optional WinTPS software allows many of the instrument's functions to be  controlled from a PC, making the units ideal for remote monitoring.

The 90 Series is proudly designed and manufactured in Australia. Our aim is to provide you with the best quality, service and value for money. The TPS Quality System has been certified in accordance with the AS/NZS ISO 9001 standard. Since 1968, TPS has built a reputation for excellent backup service that is second to none.


Specifications

Dissolved Oxygen
Ranges       : 0 to 30.00 ppM (mg/L)
               0 to 300.0 %Saturation
Resolution   : 0.01 ppM (mg/L)
               0.1 %Saturation
Accuracy     : ±0.02 ppM (mg/L)
               ±0.2 %Saturation
Temperature
Compensation : Automatic for 
               solubility (ppM only) 
               and membrane 
               permeability.
Zero
Calibration  : Automatic at less 
               than 5%.
Span
Calibration  : Automatic in air.

Temperature
Range        : -30.0 to 110.0 OC
Resolution   : 0.1 OC
Accuracy     : +/-0.2 OC
Calibration  : Automatic, 1 or 2 
               point

Salinity Correction
Manual salinity correction,
0 to 50.00 ppK

Good Laboratory Practices
Date, Time and Value of last calibration for each parameter are stored. This information can be recalled or sent to the RS232 port at any time.

Warning of failed calibration is provided.

All readings stored in memory are stamped with the date and time.

Datalogging
Memory Capacity
9340 readings (7230 with extra data input active).

Extra Data Input
2 extra items of data can be input when using the Notepad function.

Each item can be a maximum of 4 characters, including a decimal point.

Extra Data items are labelled A and B.

Automatic Datalogging
The 90-D can be programmed to...
Automatically log from 1 to 288 readings per day.

Automatically log at up to 12 specific times of the day.

Automatically log readings at a preset interval for a preset duration.

RS232 Port
8 Bits, No Parity, 1 Stop Bit, 
XON/OFF Protocol.
300, 9600, 19200 baud available.

Display
2 line x 40 Character alphanumeric LCD shows all readings simultaneously.

Keypad
5 Function keys, Menu key, 14 data entry keys, OFF, ON.

Dimensions
230  x 140 x 100 mm

Mass
Meter only   : Approx 1.5 kg
Full Kit     : Approx 5.0 kg

Environment
Temperature  : 0 to 45 OC
Humidity     : 0 to 90% R.H.

Power
7.2V Rechargeable NiCad Battery.
Any 12VDC supply will recharge the battery.


Ordering Information

                       Part No
90-D....................123145

Kit Includes
Battery Charger.........130009
(Supplied to suit country)
90-D Handbook...........130050

Sensors and Cables
YSI DO2 Sensor,no cable.123204
3m cable for 123204.....123215
5m cable for 123204.....123219
7.5m cable for 123204...123216
15m cable for 123204....123217
60m cable for 123204....123218
Extra cable, per metre..130040

YSI non-stirring BOD....123214

YSI self-stirring BOD...123213

                       Part No
Options
Submersible DO2 Stirrer.123306

RS232 Cable.............130015

Communication Software
for Windows.............130086

Solar Panel.............130012

Clip lead for external 
12V battery.............130013

Hard carry case.........130058

Download this Specification Sheet in PDF format.

Download the full colour 90 Series Brochure (1.45 MB PDF).

Download the handbook for this instrument.

Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer.

If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link.

 

TPS reserves the right to change any part of this specification without notice.
Version 6.1