Field-Lab Analysers for pH, mV, Conductivity, TDS,
Dissolved Oxygen, Turbidity & Temperature

|
|

Full Size Image |
 | 90FL
measures pH, Conductivity, TDS, Dissolved Oxygen & Temperature
|
 | 90FL-MV measures pH, mV, Conductivity,
TDS, Dissolved
Oxygen & Temperature
|
 | 90FL-T measures pH, mV, Conductivity, TDS, Dissolved Oxygen, Turbidity & Temperature
|
 | Automatic calibration
|
 | Automatic datalogging and Computer
interfacing standard (cable sold
separately) |
|
| The TPS range of Field Lab Analysers provide a complete
measurement solution for several of the most important water quality
parameters.
User-friendly
All measurements are shown simultaneously on the 80 character
display. There is no need to change modes to check any of your vital
data. The user-friendly menu system guides the operator through all
operations such as calibration, setup etc. Full text help and error messages
are provided along the way.
Waterproof
The 90 series is designed for rugged field
applications in wet environments. The case, keypad and connectors are
rated to IP65.
Good Laboratory Practices
To comply with GLP guidelines, the date, time and results of the last
calibration are stored in memory, along with the unit's serial
number. This data can be displayed or sent directly to the
RS232 port. Warning of failed calibration is provided. All readings stored
in memory are stamped with the date and time.
Notepad Function
A standard feature of the 90 series is the Notepad function. Up to 8100
sets of readings (depending on model) can be recorded for later review.
These can be downloaded to a printer or computer via the RS232 port.
For added functionality, the user is able to enter up to two
additional items to be tagged on to the reading. Many operators use
this function as a pond or site identifier, depth or readings
from other instruments. |
Datalogging
Automatic datalogging provides the capability to automatically record up
to 8100 sets of readings (depending on model) at user-set intervals. The
unit remains dormant between readings and only wakes up
whenever a reading is due. Battery life is considerably improved with
this facility.
RS232 Port
All recorded data can be downloaded directly to a Printer or Computer
with the standard RS232 port (cable sold separately). With the WinTPS
communication software, many instrument functions can be controlled
from the computer. This makes the units ideal for remote monitoring.
The 90 Series is proudly designed and manufactured in Australia.
Our aim is to provide you with the best quality, service and value
for money. The TPS Quality System has been certified in
accordance with the AS/NZS ISO 9001 standard. Since 1968, TPS has
built a reputation for excellent backup service that is second
to none. |

Specifications
|
pH
Range
: 0.00 to 14.00 pH
Resolution : 0.01
pH
Accuracy
: ±0.01pH
Impedance :
>3 x 1012 Ohms
Asymmetry :
-1.00 to +1.00 pH
Range
: 85 to 105%
Temperature
Compensation : Automatic, 0 to
100OC
Calibration : 2 Point
automatic
pH Buffers : Auto
recognition of
pH4.00, pH6.88, pH7.00,
pH9.23 and pH10.06.
Other buffers can be
keyed in at
calibration.
Millivolts (90FL-T & 90FL-MV only)
Range
: 0 to +/-1999 mV
Resolution : 1 mV
Accuracy
: +/-1 mV
Conductivity
Ranges
k=10 Sensor : 0 to 200.0
uS/cm
0 to 2000 uS/cm
0 to 20.00 mS/cm
0 to 200.0 mS/cm
k=1 Sensor : 0 to
20.00 uS/cm
0 to 200.0 uS/cm
0 to 2000 uS/cm
0 to 20.00 mS/cm
k=0.1 Sensor : 0 to 2.000 uS/cm
0 to 20.00 uS/cm
0 to 200.0 uS/cm
0 to 2000 uS/cm
Resolution : 0.05%
of full scale of
selected range.
Accuracy
: ±0.5% of full scale of
selected range at 25OC.
Temperature
Compensation : All readings
automatically
normalised to 25OC at
-2.2%/OC.
Zero
Calibration : Automatic
in air.
Span
Calibration : Automatic
to user-
defined standard.
TDS
Ranges
k=10 Sensor : 0 to 100.0
ppM
0 to 1000 ppM
0 to 10.00 ppK
0 to 100.0 ppK
k=1 Sensor : 0 to
10.00 ppM
0 to 100.0 ppM
0 to 1000 ppM
0 to 10.00 ppK
k=0.1 Sensor : 0 to 1.000 ppM
0 to 10.00 ppM
0 to 100.0 ppM
0 to 1000 ppM
Resolution : 0.1%
of full scale of
selected range.
Accuracy
: ±0.5% of full scale of
selected range at 25OC.
Temperature
Compensation : All readings
automatically
normalised to 25OC at
-2.2%/OC.
Zero
Calibration : Automatic
in air.
Span
Calibration : Automatic
to user-
defined standard.
Dissolved Oxygen
Ranges
: 0 to 32.00 ppM (mg/L)
0 to 320.0 %Saturation
0 to 66.0 % Gaseous
Resolution : 0.01
ppM (mg/L)
0.1 %Saturation
0.1 % Gaseous
Accuracy
: ±0.02 ppM (mg/L)
±0.3 %Saturation
±0.1 % Gaseous
Temperature
Compensation : Automatic for
solubility (ppM only)
and membrane
permeability.
Zero
Calibration : Automatic
at less
than 5%.
Span
Calibration : Automatic
in air. |
Turbidity
(90FL-T only)
Range
: 0 to 1000 NTU
Linearity :
3%
Temperature
Coefficient : <-0.3%/OC,
0 to 40OC
Zero
Calibration : Automatic
in distilled
water.
Span
Calibration : Automatic
to user-
defined standard.
Temperature
Range
: -10.0 to 110.0 OC
Resolution : 0.1 OC
Accuracy
: +/-0.2 OC
Calibration : Automatic,
1 or 2
point
Good Laboratory Practices
Date, time and value of last calibration for each parameter
are
stored. This information can be
recalled or sent to the RS232
port
at any time.
Warning of failed
calibration is provided.
All readings stored in
memory are stamped with the date and time.
Datalogging
Memory Capacity
90FL : 8100
readings (6500 with
extra data input active).
90FL-MV : 7200 readings (5900
with
extra data input active).
90FL-T : 6500 readings
(5400 with
extra data input active).
Extra Data Input
2 extra items of data can be
input when using the Notepad
function.
Each item can be a maximum of 4
characters, including a decimal
point.
Extra Data items are labelled A
and B.
Automatic Logging
All 3 models can be
programmed to...
- Automatically log from 1 to
288
readings per day.
- Automatically log at up to 12
specific times of the
day.
- Automatically log readings at
a
preset interval for a
preset
duration.
RS232 Port
8 Bits, No Parity, 1 Stop Bit,
XON/OFF Protocol.
300, 9600 & 19200 baud
available.
Display
2 line x 40 Character
alphanumeric LCD
shows all readings
simultaneously.
Keypad
5 Function keys, Menu key, 14
data entry keys, OFF, ON.
Dimensions
230 x 140 x 100 mm
Mass
Meter only : Approx
1.5 kg
Full Kit
: Approx 6.5 kg
Environment
Temperature : 0 to 45 OC
Humidity
: 0 to 90% R.H.
Power
7.2V Rechargeable NiCad Battery
Any 12VDC supply will recharge
the battery. |

Ordering Information
|
Part No
90FL....................126103
90FL-MV.................130018
90FL-T..................126105
Kit Includes
pH6.88 Buffer, 200mL....121306
pH4.00 Buffer, 200mL....121381
2.76mS/cm Cond Std, 1L..122305
Battery Charger.........130009
(Supplied to suit country)
Handbook................130050
(1 Litre Salinity or TDS standard
to suit k=10, k=1 or
k=0.1
sensor is also supplied)
Sensors
pH, Submersible, 5m.....111224
ORP, Submersible, 5m....111260
(90FL-MV only)
k=10 Cond/Salinity, 5m..122218
k=1 Cond/Salinity, 5m...122196
k=0.1 Cond/TDS, 5m......122197
YSI DO2 Sensor,no
cable.123204
5m cable for YSI Sensor.123219
Turbidity Sensor,.......125186
(90FL-T only)
5m cable for Turbidity..125187 Temperature Sensor, 5m..124210
(required only if Conductivity
sensor is not used) |
Part No
Options
Submersible DO2
Stirrer.123306
RS232
cable.............130015
WinTPS Communication
Software
for Windows
95,98&ME....130086
12V Solar
Panel.........130012
Clip lead for external
12V battery.............130013
Hard carry
case.........130058
Probe holder for 90FL &
90FL-MV, 5m.............121343
Probe
holder,90FL-T,5m..121345
180NTU Primary Turbidity
standard, 1L............125200
360NTU Secondary Turbidity
standard, 1L............125204 |
TPS reserves the right to change any part of this
specification without notice.
Version 6.2
Copyright © 2002-2004 T.P.S. Pty Ltd |